Step 7

When you wish to change the registered camera numbers, it
is possible to change the order of the camera numbers.

The registered cameras will be displayed in the order of 1,
2 ...16 at the upper left corner of the screen to the upper
right corner of the screen. (4 multi-screen segments when 4
cameras are connected in the system, 9 multi-screen seg-
ments when 9 cameras are connected, 16 multi-screen seg-
ments when 12 cameras are connected)
Using the mouse, drag a desired camera image and drop
the desired position. The order of the camera numbers will
be changed.
To change the positions of the camera titles together with
the order of the camera numbers, check "Also change cam-
era titles".

[Camera status]
The model numbers and statuses of each camera will be
displayed in a list.

Displaying image: Displays the images from the camera

using the IP address that is newly registered or that
has already been registered.

Changing IP address: Images are being obtained from

the camera whose IP address has been changed.

Undetectable: Cannot obtain images from the camera.
Authentication error: Failed in the authentication to dis-

play images from the camera.

Important:

• If "Undetectable" is displayed, check the camera con-

nections, and retry the camera registration.

• If "Authentication error" is displayed, format the camera

and retry the camera registration by referring to the oper-
ating instruction of the camera.

• If the registered camera is not correctly detected or if

you wish to change the camera settings, change the
registered information on the "Basic setup" menu - the
"Camera" page - the "Camera registration" tab.
(☞ Page 44).


[Refresh] button
Obtains the latest image from the camera that has been
replaced.

[Exit] button
Exits the setup menu and returns to the top screen of the
setup menu.

[Next] button
Proceeds to the settings for recording.

[Addition] button
Detects only the added or replacing cameras.
The models and results of the detected cameras will be dis-
played. Make sure that the model numbers of all the con-
nected cameras are being displayed.

Important:

• Do not click [New] button if some cameras are already

being operated. All the connected cameras will be given
new IP addresses.

• Cameras newly added after the operation start will be

registered in the default settings. To conform the settings
to those of the registered cameras, perform the settings
for the added cameras.


[Camera]
Up to 16 cameras can be connected.

[Model]
When Panasonic network cameras are used, the model
numbers will be displayed.

[Results]

New: Displayed when the camera is newly connected to

the recorder.

Replaced: Displayed when the camera has been

replaced by another one.

Added: Displayed when the camera connection is added

to the recorder.

Registered: Displayed when the camera has already

been registered.

Lost: Displayed when the registered camera is not

detected.

Blank: No camera is detected.

Step 6

Click the [Next] button.
→ IP address will be given to the cameras newly connect-

ed, replaced or added, and the images from the camera
will be displayed on the operational screen.

Note:

• When the detected cameras are registered, other login

users will forcibly be logged out.

• All recordings will stop in the process of the camera reg-

istration.

• On "Easy Start", it is impossible to register the cameras

in other subnets via the same router.

• For the security enhancement, camera detection will

become impossible when 20 minutes have passed. That
depends on the camera models. Refer to the operating
instructions of the camera for further information.

• When "On" is selected for the "DHCP" setting of the

detected cameras, the recorder will forcibly change the
setting to "Off" to give the IP addresses automatically.

• When the [Cancel] button is clicked, the top screen of

"Easy Setup" (the menu to set the date & time) without
applying the camera detection result.