Configure event-related settings [event setup] tab – Panasonic WJ-NV200 - User Manual

Page 52

Advertising
background image

52

Set up recording for individual cameras [Advanced recording setup]

Set up items such as the image capture size, frame rate and image quality for individual cameras.
Clicking the [Advanced >] button on the [Recording setup] tab will open the advanced setup page.

[Compression]
The compression method selected when registering camera
will be displayed.

[Image capture size]
Select a resolution for images to be recorded.

QVGA(320x240)/ VGA(640x480)/ SXVGA(1280x960)

Default: VGA(640x480)

Note:

• Depending on the model of the camera, the camera may

restart when the image capture size is changed. The
restart will be detected as a communication error, but
that is not a malfunction.

Important:

• When the compression method of the camera is MPEG-

4, SXVGA(1280x960) is unavailable.


[Rate] (Frame rate) (
Page 50)

[Quality] (Image quality) ( Page 50)

[Audio]
Select whether or not to record audio together with images.

On: Audio will be recorded.
Off: Audio will not be recorded.

Default: Off

[Recording]
Select whether or not to apply schedule recording.

On: Applies schedule recording.
Off: Does not apply schedule recording.

Default: On

[Saving]
Select whether or not to apply the HDD saving mode.

Depend: Applies the HDD saving mode.
Except: Does not apply HDD the saving mode. Performs

recording at the selected frame rate.

Default: Depend

[Referenced recording days] ( Page 50)

[Back] button
Click the button after completing the settings. The screen
returns to the [Recording setup] tab.

Configure event-related settings [Event setup] tab

Configure event-related settings such as the alarm output duration and buzzer duration.

Alarm action

Configure alarm-related items such as alarm output duration
and alarm auto reset.

[Output duration]
Select the output duration for the alarm signal output from
the terminal on the recorder’s rear panel when an alarm
occurs. When "0 s" is selected, alarm signals will not be out-
put.

0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: Alarm output will continue until the alarm action is

reset. Refer to the Operating Instructions (PDF) for
further information about alarm reset.

Rec.: Output of the alarm signal will continue during

event recording.

Default: 2 s

[Buzzer duration]
Set the duration of the buzzer sound when an alarm occurs.
When "0 s" is selected, the buzzer will not sound.

0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: Alarm output will continue until the alarm action is

reset. Refer to the Operating Instructions (PDF) for
further information about alarm reset.

Advertising