Panasonic WJ-NV200 - User Manual

Page 53

Advertising
background image

53

Rec.: Output of the alarm signal will continue during

event recording.

Default: 2 s

[Auto reset time]
Set the time for automatically resetting the alarm action.

2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min/ 3 min/ 5 min
Ext.: Alarm output will continue until the alarm action is

reset. Refer to the operating instructions (PDF) for
further information about alarm reset.

Default: Ext.

Note:

• If the time set for "Output duration" or "Buzzer duration"

is longer than that set for "Auto reset time", the time set
for "Auto reset time" will be applied.

[Message display]
Select whether or not to display a message on a PC con-
nected to a network when an alarm occurs.

On: Display a message.
Off: Does not display a message.

Default: On

Advanced event setup

Configure advanced settings for individual alarm types (ter-
minal alarm, camera site alarm, command alarm, and face
matching alarm*). Clicking the [Advanced >] button for each
item will open the respective "Advanced setup" .

Set up terminal alarm [Advanced terminal alarm setup]

Configure the settings relating to the recording triggered by an alarm signal supplied to the ALARM/CONTROL connector of the
recorder from an external alarm device such as a door sensor.
Configure the necessary settings for each alarm input terminal of the ALARM/CONTROL connector on the rear panel of the
recorder.

Advanced terminal alarm setup

[Mode]
Select the action to be taken when an alarm signal is sup-
plied.

Recording & alarm action: All event actions will be per-

formed according to the settings.

Recording only: Only recording, filing of event logs, and

moving the camera to a preset position will be per-
formed.

Off: Only filing of event logs will be performed.

Default: Recording & alarm action

[Setup by terminal]
Set up individual terminals numbered from 1 to 9.

[Recording camera]
Select the camera for recording. When "Off" is selected,
recording will not be performed.
Default: Camera number associated with the terminal num-

ber

[Preset]
Select the camera preset position (001 to 256) to which the
camera is to be moved with an alarm signal is received. If
"---" is selected, the camera will not be moved to a preset
position.

[Terminal output]
Choose whether or not to output an alarm signal from the
alarm output terminal of the ALARM/CONTROL connector
on the recorder’s rear panel when an alarm signal is
received.

On: Outputs alarm signals.
Off: Does not output alarm signals.

Default: On

[Terminal input]
Select the terminal status for supplying an alarm signal to the
alarm terminal.

N.O. (Normally Open): Signals will be supplied when

short-circuited.

N.C. (Normally Close): Signals will be supplied when

open-circuited.

Default: N.O.

[Back] button
Click the button after completing the settings. The screen
returns to the [Event setup] tab.