TROUBLESHOOTING

TROUBLE

PROBABLE CAUSE

REMEDY

6. Pump takes too much

A. Damaged impeller

Inspect, replace if damaged.

power

B. Foreign object lodged between Remove object as required.

impeller and bowl

C. Specific gravity higher than

Test liquid for viscosity and

pump designed for

specific gravity.

D. Viscosity too high, partial

Check for both. They can cause

freezing of pumpage

drag on impeller.

E. Defective bearing

Replace bearing, check shaft or

shaft sleeve for scoring.

F. Packing is too tight

Release gland pressure.

Retighten. (See page 15.) Keep

leakage flowing. If no leakage,

check packing, sleeve or shaft.

7. Pump is too noisy

A. Cavitation

Same as Item 3-E.

B. Bent shaft

Straighten as required. See

Page 13 for runout limits.

C. Rotating parts binding, loose

Replace as required.

or broken.

D. Bearings are worn out

Replace bearings.

E. Resonance

Check piping strain, consult factory.

8. Excessive vibrations

A. Coupling misalignment, bent Determine cause utilizing shaft

impeller unbalance, worn

vibration frequency analyzer

bearings, cavitation, piping

and/or pump disassemble.

strain and/or resonance

Complex problem may require

factory service assistance.

B. Motor or gear driveshaft end

See Installation of Hollow Shaft

play maladjustment

Driver (VHS), Page 19.

C. Bent shaft

Straighten as required. See

Page 13 for runout limits.

D. Crooked well.

Survey the well and consult factory.

9. Pump leaks excessively

A. Defective packing

Replace worn packing.

at stuffing box

B. Wrong type of packing

Replace packing not properly

installed or run-in. Replace

improper packing with correct

grade for liquid being pumped.

10. Stuffing box is

A. Packing is too tight

See item 6-F.

overheating

B. Packing is not lubricated

Release gland pressure and

replace all packing if burnt or

damaged. Re-grease packing

as required.

C. Wrong grade of packing

Consult factory.

D. Stuffing box improperly packed Repack stuffing box.

11. Packing wears too fast

A. Shaft or shaft sleeve worn

Pull pump and remachine, or

replace shaft and/or sleeve.

B. Insufficient or no lubrication

Repack and make sure packing

is loose enough to allow some

leakage.

C. Improperly packed

Repack properly, make sure all

old packing is removed and

stuffing box is clean.

D. Wrong grade of packing

Consult factory.

Advertising