3. Hold the shaft in this position by inserting a long

capscrew (or all thread rod with a hex nut) with an

assembly jig into the bottom end of the suction hub

and secure tight into the threaded hole at the end

of the shaft. Be sure the shaft has been cleaned and

checked for straightness.

4. Slide the first impeller over the shaft until it seats on

the suction bowl/bell.

NOTE: If there are different diameter impellers, put the

large diameter impeller at the lower stage.

5. Insert a screwdriver into the slot in the taperlock

(677) to spread the slot and slide the taperlock over

the pump shaft. Hold the impeller against bowl and

slide the taperlock into the impeller hub. Be sure the

taperlocks have been cleaned and are dry.

6. Hold impeller firmly against the suction bowl/bell

and drive the taperlock into place with a taperlock

driver, (See Figure 22). After the impeller is secured

in position, the top end of the taperlock should be

1/8” above the impeller hub.

7. Slide intermediate bowl (670) onto shaft and secure

with capscrews provided.

8. Repeat preceding procedure for number of stages

required.

9. Remove long capscrew and the assembly jig at the

end of suction hub and check that the shaft rotates

freely without dragging or binding. Also check for

adequate lateral (end play).

FINAL ASSEMBLY
After reassembling the bowl assembly, see Section 3 for

installation. Refer to Section 4, for startup and operation

procedures.