10.7

[02 Administrator Setting] - [01 System Setting]

10

10.7.27

[04/05 Expert Adjustment] - [04 Quality Adjustment] - [06 Print Gamma Sen-
sor Adj. (RU)]

Correct the internal IDC sensor using the color density sensor attached to Relay Unit RU-508 in order to
make the gamma correction properly.

The printer gamma correction curve formed by the color density sensor cannot be adjusted.

NOTICE

The title number given to [Expert Adjustment] will be [04] for the machine without Image Controller IC-601,
or [05] for the machine with that option mounted.

1

Follow the procedure on page 10-3 to display the Administrator Setting Menu Screen.

2

Press [01 System Setting], [04/05 Expert Adjustment], [04 Quality Adjustment], and [06 Print Gamma
Sensor Adj. (RU)] in sequence.

The Printer Gamma Sensor Adjustment Screen will be displayed.

3

Press the desired screen key to select the screen to be adjusted.

4

Press [Print Mode].

The Print Mode Screen will be displayed.

5

Select a tray to be used for the adjustment, then press Start on the control panel.

A printed chart will be output through the color density sensor of Relay Unit RU-508 for color meas-
urement.

The Printer Gamma Sensor Adjustment Screen will be restored.

The measured chart will be delivered to an output tray.

% When [Input Sensor Value Error] is displayed, check the size of the output chart. Repeat steps 4 to

5 until the error message does not appear.

% When [Acquisition Sensor Value Error] or [Regression Calculation Error] is displayed, repeat steps 4

to 5 until the error message does not appear.

% If the error message displays repeatedly, contact your service representative.

% To reset the adjustment value for the sensor of selected screen, press [Reset Adj. Data].

6

Press [Return] to restore the Quality Adjustment Menu Screen.