System, Output select, Input – Boss Audio Systems Boss CDSM AMP EFFECTS PROCESSOR GT-100 User Manual
Page 26: Global eq, Total, Phrase loop, Play option
26
SYSTEM
OUTPUT SELECT
Specify the device (amp) that’s connected to the OUTPUT jacks .
Parameter
Value
Explanation
SELECT
JC-120
Choose this setting if the GT-100 is connected
to the guitar input of a Roland JC-120 guitar
amp .
SMALL AMP
Choose this setting if the GT-100 is connected
to a small guitar amp .
COMBO AMP
Choose this setting if the GT-100 is connected
to the guitar input of a combo-type guitar
amp (i .e ., a single unit that contains the amp
and speaker) other than the JC-120 .
For some types of guitar amps, the “JC-120”
setting might produce better results .
STACK AMP
Choose this setting if the GT-100 is connected
to the guitar input of a stack-type guitar amp
(i .e ., one in which the amp and speaker are
separate units) .
JC-120 RETURN
Choose this setting if the GT-100 is connected
to the RETURN jack of the JC-120 .
COMBO RETURN
Choose this setting if the GT-100 is connected
to the RETURN jack of a combo-type guitar
amp .
STACK RETURN
Choose this setting if the GT-100 is connected
to the RETURN jack of a stack-type guitar
amp . You should also choose the “STACK
RETURN” setting if you’re using a guitar
power amp together with a speaker cabinet .
LINE/PHONES
Choose this setting if you’re using
headphones, or if the GT-100 is connected to
a keyboard amp, mixer, or digital recorder .
INPUT
Adjust the input level according to the output level of the guitar that
you’ve connected .
Parameter
Value
Explanation
INPUT LEVEL
-20–+20 dB
Adjusts the guitar input level .
GLOBAL EQ
This adjusts the tone of the OUTPUT regardless of the equalizer on/off
settings of individual patches .
Parameter
Value
Explanation
LOW GAIN
-20–+20 dB
Adjusts the low frequency range tone .
MID GAIN
-20–+20 dB
Adjusts the middle frequency range tone .
MID FREQ
20 .0 Hz–10 .0 kHz
Specifies the center of the frequency range
that will be adjusted by the MID GAIN .
MID Q
0 .5–16
Adjusts the width of the area affected by the
EQ centered at the MID FREQ . Higher values
will narrow the area .
HIGH GAIN
-20–+20 dB
Adjusts the high frequency range tone .
TOTAL
These parameters control the threshold level of the noise suppressor used
by each patch, the overall reverb level, and the overall output . They do not
affect the settings of each patch .
Parameter
Value
Explanation
NS THRESH
-20–+20 dB
Control the threshold level of the noise
suppressor used by each patch . This does not
affect the settings of each patch .
* If you want to use the settings specified for
each patch, set this to 0 dB .
REVERB
0–200%
Adjusts the reverb level specified for each
patch .
It is useful to adjust the reverb level
appropriately for the space in which you’re
performing . This does not affect the settings
of each patch .
* If you want to use the settings specified for
each patch, set this to 100 % .
MAIN
OUTPUT
LEVEL
-10 dB, +4 dB
Specifies the output reference level as
appropriate for the input level of the device
connected to the OUTPUT jacks .
PHRASE LOOP
Here are various settings for the Phrase Loop function .
Parameter
Value
Explanation
MODE
PERFORM
The sound processed by the effects will be
recorded .
This lets you create a variety of performances
by layering different sounds .
PATCH EDIT
The sound before being processed by the
effects will be recorded, and the effects will
be applied when the loop is played back .
This is a convenient way to adjust the effects,
or to compare the sound of different patches .
REC MODE
MONO
The phrase will be recorded in monaural
(maximum 38 seconds) .
STEREO
The phrase will be recorded in stereo
(maximum 19 seconds) .
PLAY LEVEL
0–120
Specifies the phrase playback volume .
PEDAL FUNC
OFF
Phrase Loop will not operate even if you
press the [PHRASE LOOP] pedal .
PHRASE LOOP
You can use the [PHRASE LOOP] pedal to
switch Phrase Loop on/off or to record .
PLAY OPTION
Here you can specify how the pedals will work during performance .
Parameter
Value
Explanation
BANK
CHANGE
MODE
WAIT
Although the indication in the display is
updated to reflect the change in the bank
when a BANK pedal is pressed, the patch will
not change until a number pedal has been
pressed .
IMMED
The patch switches instantly when a BANK
pedal or any of the number pedals is pressed .