SYSTEM

29

Parameter

Value

Explanation

MIX LEVEL

Adjusts the level of the audio input from the computer that

will be mixed with the sound processed by the GT-100’s effects

when “USB IN-OUT MODE” is not set to “REAMP” .

0–200 %

Adjusts the level of the audio input from the

computer that will be mixed with the sound

processed by the GT-100’s effects .

INPUT LEVEL

Adjusts the input level from the computer to the GT-100’s effects

when “USB IN-OUT MODE” is set to “REAMP” .

-20–+20 dB

Adjusts the input level from the computer to the

GT-100’s effects .

OUTPUT LEVEL

Adjusts the level of the output from the GT-100 to the computer .

0–200%

Adjusts the level of the output to the computer .

DIR . MONITOR

Switches the output of the GT-100 sound to the OUTPUT and

PHONES jacks .

* This setting cannot be saved . It is set to ON when the power

is turned on .

* If you are using the special driver, you can control DIR .

MONITOR On/Off from ASIO 2 .0 - compatible application .

OFF

Set this to Off if transmitting audio data

internally through a computer (Thru) .
No sound is heard at this time unless the setting

for the computer is Thru .

ON

The GT-100 sound is output . Set this to ON

when using the GT-100 as a standalone device,

without connecting to a computer (only USB

input sound will be output if this is set to Off) .

DIR . MONITOR

CMD

This setting determines whether or not the command (the

Direct Monitor command) controlling the Direct Monitor setting

is enabled .

DISABLE

The Direct Monitor command is disabled,

maintaining the Direct Monitor mode set by the

GT-100 .

ENABLE

The Direct Monitor command is enabled, allow-

ing the Direct Monitor mode to be switched

from an external device .

MIDI SETTING

Here you can make settings for using the GT-100 connected with an

external MIDI device or with a second GT-100 unit .

Parameter

Value

Explanation

RX CHANNEL

This sets the MIDI channel used for receiving MIDI messages .

Ch . 1– Ch . 16

Specifies the receive channel .

OMNI MODE

This makes the settings for the channels used for MIDI

information .

OFF

Information is received on the channel specified

by the RX CHANNEL setting .

ON

Messages are received on all channels, regard-

less of the MIDI channel settings .

TX CHANNEL

This sets the MIDI channel used for transmitting MIDI messages .

Ch . 1– Ch . 16 . Specifies the transmit channel .

RX

Transmits on the same channel as the RX

CHANNEL .

DEVICE ID

This sets the MIDI Device ID used for transmitting and receiving

Exclusive messages .

1–32

Sets the MIDI Device ID .

Parameter

Value

Explanation

SYNC

CLOCK

This setting determines the basis used for synchronizing

the timing for effect modulation rates and other time-based

parameters .

* When you have an external MIDI device connected, the

MASTER BPM is then synchronized to the external MIDI

device’s tempo, thus disabling the MASTER BPM setting . To

enable setting of the MASTER BPM, set to “INTERNAL .”

* When synchronizing performances to the MIDI Clock

signal from an external MIDI device, timing problems in the

performance may occur due to errors in the MIDI Clock .

AUTO

Operations are synchronized to the MIDI Clock

received via MIDI . However, operations are

automatically synchronized to the GT-100’s

internal Clock if the GT-100 is unable to receive

the external Clock .

INTERNAL

Operations are synchronized to the GT-100’s

internal Clock .

MIDI IN

SELECT

This selects whether MIDI messages will be received from the

MIDI IN connector or from the USB port .

USB (AUTO)

MIDI messages will be received via the USB port .

* If the USB port is not connected to a

computer, MIDI messages will be received

from the MIDI IN connector .

MIDI

MIDI messages will be received from the MIDI

IN connector .

PC OUT

This setting determines whether or not Program Change

messages are output when patches are switched on the GT-100 .

* On the GT-100, Bank Select messages are output simultane-

ously with Program Change messages .

OFF

Program Change messages are not output, even

when patches are switched .

ON

Program Change messages are simultaneously

output when patches are switched .

MAP

SELECT

This setting determines whether patches are switched according

to the Program Change Map settings, or to the default settings .

FIX

This deactivates the Program Change Map .
Switches to the patches according to the default

settings .

PROG

This activates the Program Change Map .
Switches to the patches according to the

Program Change Map .

PH .LOOP

OUT

This sets the controller number when [PHRASE LOOP] pedal

switch operation data is output as Control Change messages .

OFF

Control Change messages are not output .

CC#1–CC#31,

CC#64–CC#95

This sets the controller number when [PHRASE

LOOP] pedal operation data is output as Control

Change messages .

ACC/CTL

OUT

This sets the controller number when [ACCEL/CTL] pedal switch

operation data is output as Control Change messages .

OFF

Control Change messages are not output .

CC#1–CC#31,

CC#64–CC#95

This sets the controller number when [ACCEL/

CTL] pedal operation data is output as Control

Change messages .

EXP OUT

This sets the controller number when [EXP] pedal operation data

is output as Control Change messages .

OFF

Control Change messages are not output .

CC#1–CC#31,

CC#64–CC#95

This sets the controller number when [EXP]

pedal operation data is output as Control

Change messages .

EXP SW

OUT

This sets the controller number when EXP PEDAL SW operation

data is output as Control Change messages .

OFF

Control Change messages are not output .

CC#1–CC#31,

CC#64–CC#95

This sets the controller number when EXP

PEDAL SW operation data is output as Control

Change messages .