Product information, Specifications – BT VP1000 User Manual

Page 65

Advertising
background image

Section 8 – General Information

BT Home Monitor ~ Issue 5 ~ 1st Edition ~ 26_01_ 04 ~ 5725

Product Information

Wireless systems are reliable and tested to high
standards. However, due to their transmitting
power and range, there are some limitations to
be considered:

• Receivers may be blocked by radio signals

occurring on or near operating frequencies,
regardless of the code selected.

• A receiver can only respond to one transmitted

signal at a time.

• Wireless equipment should be tested regularly

to determine whether there are sources of
interference and to protect against faults.

Specifications

CONTROL PANEL

Sensor
Numbers:

28 fully supervised wireless

User Codes:

8 codes, 4 digits each

Control
Facilities:

Integral keypad

PowerCode / Code-Secure(tm)
hand-held transmitters

Wireless Keypad

Display:

Single line, backlit 16-character
LCD and 4 LED indicators

Setting Modes: ON, HOME, Sensor Off

Sensor

Home, House & Home,

Responses:

Walk-Thru, Entry 1, Entry 2,
Help Silent, Fire, Emergency,
Alarm and Non Alarm

Siren Signals:

Continuous (intrusion / 24 hours /
panic); triple pulse - pause - triple
pulse... (fire)

Siren Timeout: Programmable

(4 minutes by default)

Internal
Siren Output:

At least 85 dBA at 3m (10ft)

Supervision:

4-hour reporting time-window

Data Retrieval: Status, alarm in memory, check

Compliance

EMC Emission:

with European EN 50081-1 1992

Standards:

RFI: EN55022 1998

EMC Immunity: EN 50082-1 1997

EMC Immunity to Conducted

RF: EN6100-4-6 1996
Telephony: TBR21 1998

Safety: EN060950 2000

Operating
Frequencies:

868.95MHz

Receiver Type: Super-heterodyne, fixed frequency

Coding:

PowerCode and / or CodeSecure

(tm)

Output Power: Maximum 10mW

Power Supply:

Plug-in transformer 230VAC,
50Hz /9VAC, 700mA

Current Drain: Approx. 95mA standby, 500 mA

at full load and in alarm

Internal Siren
Current (INT):

550* mA max.

High Current /
Short Circuit

All outputs are protected

Protection:

(current limited)

Total Home
Monitor Output
Current:

600mA max.

Internal Siren
Output Current:
50mA max.

Backup Battery: (Provides power for at least

8 hours). Six 1.2V NiMH
rechargeable AA Cells, 1300mAh.
Or six 1.2V NiCad AA Cells,
650mAh

Battery Test:

Once every 24 hours, and once
per hour during AC power loss

Built-in Modem: 300 baud, Bell 203 protocol

Data Transfer to
Local Computer:
Via RS232 serial port

Reporting
Format Options:
SIA

Operating
Temp. Range:

0°C to 49°C (32°F to 120°F)

Storage
Temp. Range:

–20°C to 60°C (–4°F to 140°F)

Humidity:

85% relative humidity at
30°C (86°F)

64

SECTION

8

Advertising