Installing nibi-16-fan-exh-a fan assemblies, Installing, Nibi-16-fan-exh-a fan assemblies – Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 200

Advertising
background image

182

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53-1002373-02

Installing a Brocade MLX-16 router

3

This message is displayed at bootup, or when the NI-MLX-1Gx48-T-A module is inserted in the
router.

When installing NI-MLX-1Gx48-T-A modules, you must upgrade the software on all installed
interface modules and management modules to the appropriate software release. For more
information refer to the Multi-Service IronWare Software Release 05.2.00 for Brocade MLX Series
and Brocade NetIron Family
. For more information on upgrading the software, refer to the
Multi-Service IronWare Software Upgrade Guide.

Installing NIBI-16-FAN-EXH-A fan assemblies

NOTE

You can remove and replace fan assemblies and switch fabric modules while the Brocade MLX
16-slot router is powered on and running.

CAUTION

To avoid overheating of the router, remove one fan assembly at a time, and replace it promptly.
Do not remove all fans from the device at once.

To install the high speed fans, you need the following:

Two high-speed fan assemblies, as shown in

Figure 128

.

A small flat-blade screwdriver.

An ESD wrist strap with a plug for connection to the ESD connector on the router chassis.

DANGER

For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor.

FIGURE 128

High-speed fan assemblies for Brocade MLX 16-slot routers

Perform these steps to replace standard rear fan assemblies with high-speed rear fan assemblies
in a 16-slot router.