If an I2C failure has not occurred, there will be no I2C messages in the static log, dynamic log, or
SNMP log server. The following example shows output from the show logging command when there
is no I2C failure.

If the system detects a major I2C failure, the system prevents the management module from
accessing devices through the l2C serial bus. The output from the show chassis command and the
show temperature command reflect this action, as shown in these examples.

The following output is from the show temperature command with the GIEI set to major severity.

Displaying device status and temperature readings

You can display the following information about the router:

Power-on priority of the device slots

Status of the fans

Temperature readings of the management, switch fabric, interface, and fan control modules
and the interval at which the system reads the temperature of these modules

MAC address of the device

Brocade# show logging

Syslog logging: enabled (0 messages dropped, 0 flushes, 1 overruns)

Buffer logging: level ACDMEINW, 50 messages logged

level code: A=alert C=critical D=debugging M=emergency E=error

I=informational N=notification W=warning

Static Log Buffer:

Apr 16 18:21:25:A:System: Power Supply 2 , middle, Not Installed (FAILED)

Apr 16 18:21:25:A:System: Power Supply 3 , top, Not Installed (FAILED)

Dynamic Log Buffer (50 lines):

Mar 28 12:36:47:A:System: Set fan speed to MED (75%)

Mar 25 21:40:47:A:System: Set fan speed to MED-HI (90%)

Mar 25 16:30:47:A:System: Set fan speed to MED (75%)

Mar 23 23:12:07:A:System: Set fan speed to MED-HI (90%)

Brocade# show chassis

*** Note: ***

*** Global I2C Error Indicator is set (severity: Major). ***

*** All I2C access are skipped. ***

*** Brocade MLX-4 device ***

---POWERS ---

Slot Power-On Priority and Power Usage:

Slot2 pri=1 module type=NI-MLX-1Gx20-GC 20-port 10/100/1000 Copper Module power usage=146W

Slot4 pri=1 module type=NI-X-OC48x4 4-port OC48/12 STM16/STM4 Module power usage=132W

---FANS ---

---TEMPERATURE READINGS ---

LP2 Sensor1: 34.500C

LP2 Sensor2: 44.125C

Brocade# show temperature

*** Note: ***

*** Global I2C Error Indicator is set (severity: Major). ***

*** All I2C access are skipped. ***

SLOT #: CARD TYPE: SENSOR # TEMPERATURE (C):

2 LP 1 34.0C

2 LP 2 44.250C

4 LP 1 36.0C

4 LP 2 45 750C