Clearing power supply failure timestamps, Displaying power supply monitoring timestamps – Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 373

Advertising
background image

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

355

53-1002373-02

Replacing a power supply

8

NOTE

A threshold value of 0 will not automatically shutdown a power supply due to failures.

For Syslog messages, please refer to Appendix A, Using Syslog in the Brocade MLX Series and
Brocade NetIron Family Configuration Guide
.

Clearing power supply failure timestamps

Use the power-supply monitoring clear command to clear all collected failure timestamps for a
given power supply, or for all available power supplies.

To clear all collected failure timestamps for a power supply, enter the following command.

Brocade(config)# power-supply monitoring clear 1

This will clear all collected failure timestamps for the Power Supply # 1

Are you sure? (enter 'y' or 'n'): y

To clear all collected failure timestamps for all available power supplies, enter the following
command.

Brocade(config)# power-supply monitoring clear all

This will clear all collected failure timestamps for all available Power Supplies

Are you sure? (enter 'y' or 'n'): y

You are asked to verify this command by entering “yes” or “no.

Syntax: power-supply monitoring clear <decimal | all>]

By default, no power-supply monitoring is configured.

The <decimal> variable specifies a power supply number, The all keyword clears all available power
supplies.

Displaying power supply monitoring timestamps

To display timestamps for failures on any power supply, enter the following command.

Brocade# show power-supply-monitoring

PS-1 PS-2 PS-3 PS-4 PS-5 PS-6 PS-7 PS-8

1 ) 0 0 0 0 0 0 0 0

2 ) 0 0 0 0 0 0 0 0

3 ) 0 0 0 0 0 0 0 0

4 ) 0 0 0 0 0 0 0 0

5 ) 0 0 0 0 0 0 0 0

6 ) 0 0 0 0 0 0 0 0

7 ) 0 0 0 0 0 0 0 0

8 ) 0 0 0 0 0 0 0 0

9 ) 0 0 0 0 0 0 0 0

The show power-supply-monitoring command displays the last 32 recorded failure timestamps for
a power supply. The current configured power supply monitoring threshold value is also displayed
at the end of the output.

Syntax: show power-supply-monitoring

Advertising