Storage environment, Safety agency approvals, Electromagnetic approvals – Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 408: Port specifications for all router models, Console port pin assignments

Advertising
background image

390

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

53-1002373-02

Port specifications for all router models

9

Storage environment

Table 66

provides the storage environment specifications for the Brocade NetIron XMR routers.

Safety agency approvals

CAN/CSA-C22.2 No. 60950-1-07/UL60950-1 – Second Edition, Safety of Information
Technology Equipment

EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and
User’s Guide

EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications
Systems

EN 60950-1:2006\IEC 60950-1:2005, Second Edition, Safety of Information Technology
Equipment

Electromagnetic approvals

FCC Part 15, Subpart B (Class A)

EN 55022 (CE mark) (Class A)

EN 55024 (CE mark) (Immunity) for Information Technology Equipment

ICES-003 (Canada) (Class A)

AS/NZ 55022 (Australia) (Class A)

VCCI (Japan) (Class A)

EN 61000-3-2

EN 61000-3-3

EN 61000-6-1

Port specifications for all router models

This section describes port specifications for all router models.

Console port pin assignments

The console port is a standard male DB-9 connector, as shown in

Figure 252

. For information

about how you can use this port, refer to

“Console port”

on page 20.

TABLE 66

Brocade NetIron XMR router storage environment requirements

Storage temperature

Storage humidity

Storage altitude

(-25° – 70° C) -13°– 158°F

95% maximum relative humidity,
non-condensing

(0 – 4500 meters) 0 – 15,000 ft