Managing the cooling system

7

Managing the cooling system

This section provides configuration, management, and monitoring information about router cooling
systems.

Configuring the cooling system

Your router is pre-configured with default settings for all cooling system parameters. Although no
initial configuration of the cooling system is necessary, you can change the settings of the following
cooling system parameters:

Low and high temperature thresholds for modules and fan speeds

Interval at which the system polls the temperature sensors on the module for a reading

NOTE

Auto control of fan speed is not monitored when cards are in interactive mode. Set fan speed to high
to prevent over-temp condition.

NOTE

Adjusting fan controls out of the default setting can negatively affect the efficient cooling of blades
and may cause a blade to overheat and shutdown.

Changing temperature thresholds for modules and fan speeds

The cooling system includes fans that operate at four speeds: low, medium, medium-high, and
high. In general, each fan speed, (except for low), has a low and high temperature threshold
associated with it, as shown in

Figure 227

. The low fan speed has a high temperature threshold

only.

NOTE

Adjusting fan controls out of the default setting can negatively affect the efficient cooling of blades
and may cause a blade to overheat and shutdown.

FIGURE 227

Fan speeds and temperature thresholds

The low and high temperature thresholds allow the router to determine the speed at which the fans
should operate. In general, the fans operate according to these guidelines:

If the temperature of all modules falls between the low and high thresholds for a fan speed, the
fan continues to operate at that speed.

Operating

Temperature

Medium

Speed

Low Speed

Med-High

Speed

High

Speed

50 55 60 65 70 75 80 85 90 95

High, 60 deg.

Low 57, deg.

High, 70 deg.

Low, 67 deg.

High, 80 deg.

Low, 77 deg. High, 85 deg.