Forcing hsf modules to operate in normal mode, Blocking discovery of g1 switch fabric modules – Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 348

Advertising
background image

330

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

53-1002373-02

Managing switch fabric modules

7

Forcing HSF modules to operate in normal mode

NOTE

This procedure requires that you restart your router.

If necessary, you can configure HSF modules to operate in normal mode using the system-init
fabric-data-mode force normal command.

Brocade(config)# system-init fabric-data-mode force-normal

Syntax: [no] system-init fabric-date-mode force-normal

If you remove the forced normal condition using the no version of this command, you must enter
the write-memory command and restart the router.

Blocking discovery of G1 switch fabric modules

NOTE

This procedure requires that you restart your router.

In a router with both standard (G1) switch fabric modules and G2 HSF modules, you can block the
discovery of the G1 switch fabric modules by entering the system-init block-g1-sfm command.

Syntax: system-init block-g1-sfm

After you enter this command, enter the write -memory command and restart the router.