Pos interface modules – Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 62

Advertising
background image

44

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

53-1002373-02

Router modules

1

NOTE

Fan upgrades are not required on Brocade MLX-16 routers.

To display information about NIBI-16-FAN-EXH-A modules installed in a 16-slot router, enter the
show chassis command.

Brocade# show chassis

*** Brocade MLX-16 chassis ***

Power 1 (H1250CFN - AC 1200W): Installed (OK)

Power 2: Installed (Failed or Disconnected)

Power 3: not present

Power 4: Installed (Failed or Disconnected)

Power 5: (H1250CFN - AC 1200W): Installed (OK)

Power 6: (30351200 - AC 1200W): Installed (OK)

Power 7: Installed (Failed or Disconnected)

Power 8: (30351200 - AC 1200W): Installed (OK)

Total power budget for chassis = 4800 W

Total power used by system core = 762 W

Total power used by LPs = 1040 W

Total power available = 2998 W

Slot Power-On Priority and Power Usage:

Slot10 pri=1 module type=NI-MLX-1Gx48-T-A 48-port 10/100/1000Base-T MRJ21

Module power usage=260W

Slot11 pri=1 module type=NI-MLX-1Gx48-T-A 48-port 10/100/1000Base-T MRJ21

Module power usage=260W

Slot13 pri=1 module type=NI-MLX-1Gx48-T-A 48-port 10/100/1000Base-T MRJ21

Module power usage=260W

Slot16 pri=1 module type=NI-MLX-1Gx48-T-A 48-port 10/100/1000Base-T MRJ21

Module power usage=260W

--- FANS ----

Bottom fan tray (fan 1): Status = OK, Speed = LOW (50%)

Bottom fan tray (fan 2): Status = OK, Speed = LOW (50%)

Bottom fan tray (fan 3): Status = OK, Speed = LOW (50%)

Bottom fan tray (fan 4): Status = OK, Speed = LOW (50%)

Bottom fan tray (fan 5): Status = OK, Speed = LOW (50%)

Bottom fan tray (fan 6): Status = OK, Speed = LOW (50%)

Rev A Back Fan A (revision 0x09): Status = OK, Speed = LOW (50%)

Rev A Back Fan B (revision 0x0c): Status = OK, Speed = LOW (50%)

The output displays firmware Revision A (Rev A) for NIBI-16-FAN-EXH-A modules. Rev A
indicates that the router contains the required rear fan modules to support the
NI-MLX-1Gx48-T-A modules. The RPM value thresholds (LOW/MED/MED-HI/HI) are also
displayed for rear fan modules.

NOTE

If the router does not contain NIBI-16-FAN-EXH-A modules, the show chassis command will not
display Rev A for rear fan modules.

POS interface modules

Brocade MLX and Brocade NetIron XMR routers support the following Packet Over SONET or SDH
(POS) interface modules:

Dual speed (OC-48c or STM-16)/(OC-12c or STM-4) – Available with 2, 4, or 8 ports

Single speed OC-192c or STM-64 – Available with 1 or 2 ports

Brocade MLXe routers support POS interface modules, beginning with release 05.0.00 and later.