Model 6036 S/N 9B0499 and Before

9-46

Section 9.

Hydraulic System

PISTON

PILOT

POPPET

PILOT

SPRING

ADJUSTMENT

SCREW

PLUG

TO

RESERVOIR

RELIEF VALVE

POPPET

CHECK VALVE

POPPET

RELIEF

AREA

1

2

3

4

5

6

7

FRAME

The relief valve setting is determined by the
compression of the pilot spring as set by the
adjustment screw. When the pressure exceeds
the relief setting, the pilot poppet acts against the
poppet spring to unseat. The fluid then flows
around the pilot poppet through cross-drilled holes
in the plug to the reservoir; some pressure is
relieved.

Due to the reduced pressure, the piston seats
against the pilot poppet. This shuts off fluid flow
through the valve and causes a low pressure area

internally. The differential pressure between the
supply pressure and the internal pressure causes
the relief valve poppet to unseat and fluid flows to
the reservoir thus relieving the pressure.

If low supply pressure should occur due to pump
cavitation, the check valve poppet will unseat and
allow fluid to flow back to the supply from the
reservoir.

Refer to paragraph 9.1 for information on relief
valve functions and testing.

Fig. 9.23 Main Control Valve Installation

1.

Cotter Pin

2.

Retaining Pin

3.

Locknut

4.

Washer

5.

Capscrew

6.

Main Control Valve

7.

Linkage

Fig. 9.24 Relief Valve Sectional View

MA0641

MA0652