Section 10.

Electrical System

Model 6036 S/N 9B0499 and Before

10-41

(3) to minimize the entry of dust between the
plate and the gauge cover (4). Leave the
ends open to provide some ventilation.

4.

Position the plate and cover under the right
console panel (5) and secure with four hex
head screws (6), lock washers (2) and hex
nuts (1).

5.

Connect any wiring removed in previous
steps.

6.

Position right console panel (5) and overlay on
control console and secure with four screws
(12).

10.8.3

Hourmeter

The hourmeter (7, Fig. 10.47) indicates the total
elapsed hours of forklift operation. It is a solid
state electronic piece of equipment except for the
number wheels, rotor and reduction gears. The
hourmeter should operate whenever the engine is
running. If the hourmeter is intermittent or fails to
operate, check for faulty wiring or connections.
Check for proper voltage at meter terminal (8 to 32
Vdc). To check accuracy observe the running
indicator flag wheel. The gauge is accurate to ±1
percent at 75 °F (24 °C).

Fig. 10.47 Gauges and Indicator Lights

1.

Nut, hex, 1/4"

2.

Lock Washer, 1/4"

3.

Gauge Mounting Plate

4.

Gauge Cover

5.

Right Console Panel

6.

Screw, hex hd 1/4 by 3/4"

7.

Hourmeter

8.

Warning Lights Gauge

9.

Seal Cap

10. Bulb Test Switch

11. Fuel Gauge
12. Flange Head Bolt
13. Bulb socket
14. Bulb
15. Connector

16. Bulb
17. Fuel gauge light assembly
18. Hex nut
19. Tooth type lock washer
20. Clip

a.

Removal of the Hourmeter

1.

Refer to paragraph 10.8.1 for removal of
gauge cluster.

2.

Disconnect spade connector at hourmeter (7,
Fig. 10.47).

3.

To remove hourmeter, loosen nut on clip
which secures hourmeter to gauge mounting
plate (3).

4.

Lift hourmeter from gauge mounting plate.

b. Cleaning and Drying

Clean the hourmeter with a clean lint-free cloth.

c.

Inspection and Replacement

Inspect the hourmeter and replace if defective. To
check operation observe the indicator flag wheel.

d. Installation of the Hourmeter

1.

Position hourmeter (7, Fig. 10.47) in gauge
mounting plate

2.

Install clip and nut which secures hourmeter to
gauge mounting plate.

3.

Refer to paragraph 10.8.2 for installation of the
gauge cluster.