5 troubleshooting – SkyTrak 6036 Service Manual User Manual

Page 184

Advertising
background image

Section 9.

Hydraulic System

9-71

Model 6036 S/N 9B0499 and Before

Trouble

Probable Cause

Remedy

9.5

TROUBLESHOOTING

Cannot Lower
Elevated load

Cavitation and Noise

Ruptured Hose

Hose Cover Sepa-
rated from Wire

Damaged Threads on
Fittings

Boom Hoist or Ex-
tend Function Slow
or Malfunctioning

Ruptured hoist or extend
hose

Loss of engine power or
hydraulic pump failure

Faulty main control valve

Fluid level in reservoir is
low

Filler/breather is clogged

Air leaks in suction line

Loose tandem pump
mounting hardware

Loose pump sections

Defective tandem pump

Damaged hose due to
tight bend

Pressure setting for main
relief valve is too high

Hose is twisted

Connections are too tight
or cross threaded

External fluid leakage at
tubes, hoses or fittings

Faulty relief valve setting

Internal leakage in cylin-
ders

Internal leakage in control
valve

Defective tandem pump

Lower load using Emergency Boom Lowering
instructions in Owners/Operators Manual.

Lower load using Emergency Boom Lowering
instructions in Owners/Operators Manual.

Repair main control valve (para 9.3.1).

Add fluid. Refer to Owners/Operators Manual.

Clean or replace filler/breather.

Using an oil can containing system fluid, squirt
a little fluid on each joint of the suction line and
tighten any joint where fluid stopped the noise.
Double clamp if necessary.

Tighten mounting capscrews to 75 lb-ft (101,7
N m).

Tighten hardware to 200 lb-ft (271,2 N m). Refer
to para 9.4.1.

Repair pump (para 9.4.1).

Replace hose and install without tight bends or
twists.

Check and set the main relief valve (para 9.1.1).

Replace and make sure the hose does not turn
as swivel fitting is tightened.

Repair hose fittings if possible or replace hose.

Check and tighten connections at valves,
pumps and cylinders. Repair or replace faulty
hose(s).

Set relief valves (para 9.1.1 and 9.1.2).

Repair cylinders as required (para 9.2.1 and
9.2.2).

Repair control valve as required (para 9.3.1).

Repair tandem pump (para 9.4.1).

Advertising