Page 26

6036/6036T

1.

The booster battery must be a 12 volt type. The
vehicle used for jump starting must have a negative
ground electrical system. To jump start the vehicle,
proceed as follows.

2.

Connect the positive (+) jumper cable to the positive
(+) post of the discharged battery.

3.

Connect the other end of the same jumper cable to
the positive (+) post of the booster battery.

4.

Connect one end of the second jumper cable to the
negative (-) post of the booster battery.

5.

Make the final cable connection to the engine block
or the furthest ground point away from the battery.

6.

Follow the steps in "Normal Starting".

7.

Remove the jumper cables in the reverse order of
their connection (i.e. negative cable ground connec-
tion first, etc.)

5.

Avoid operating in too high a gear when moving a
heavy load as this may cause excessive "lugging".
This occurs when the engine will not respond to a
throttle increase. Use a lower gear when moving a
heavy load; a higher gear when moving a light load.
Selecting the correct gear ratio will save fuel and
prolong engine life.

IMPORTANT: Check warning lights frequently during
operation. Any abnormal indication or vehicle malfunction
should be corrected as soon as possible.

Operating

Starting Travel

1.

Enter operator cab, fasten seat belt, start engine
and disengage emergency brake switch.

2.

Move range select lever to the desired gear

(1, 2 or 3).

3.

Move travel select lever to forward (F) or reverse
(R) as needed.

4.

Use accelerator pedal to control ground speed.