Air cleaner and restriction indicator, Page 49 – SkyTrak 6036 Operation Manual User Manual

Page 55

Advertising
background image

Page 49

6036/6036T

2. Air Cleaner and Restriction Indicator

Figure 23

RESTRICTION INDICATOR

INDICATOR WINDOW

AIR CLEANER

VACUATOR VALVE

OA0212

Figure 24

A.

Filter Check (Daily or 10 Hour Intervals)

1.

Ground the carriage, place the travel select lever
in Neutral (N), engage the emergency brake
switch and shut off the engine.

2.

Unlock and open the left rear engine access door
to access air cleaner restriction indicator (Figure
23). Check indicator. If red band has appeared,
filter must be cleaned or replaced.

NOTE: Depress button on top of indicator to reset
indicator after servicing element.

IMPORTANT: Only remove canister cover to service
the elements as restriction indicator indicates or
during scheduled maintenance intervals. Excessive
access to check or clean an element can lead to
premature element failure and increase the possibility
of dirt entering the engine.

3.

Remove dust from vacuator valve (Figure 24) by
squeezing bottom of vacuator to allow loose
particles to fall out. Replace elements, if re-
quired, as described in paragraph 2B.

OA0203

TEXT

HERE

Advertising