Powering up, Initializing the system, Heat dissipation – ElmoMC ExtrIQ Digital Servo Drives-Solo Hornet User Manual

Page 51: Solo hornet thermal data

Advertising
background image

Solo Hornet Installation Guide

Installation

MAN-SOLHRNIG (Ver. 1.003)

www.elmomc.com

51

4.10. Powering Up

After the Solo Hornet is connected to its device, it is ready to be powered up.

Caution: Before applying power, ensure that the DC supply is within the
specified range and that the proper plus-minus connections are in order.

4.11. Initializing the System

After the Solo Hornet has been connected and mounted, the system must be set up and
initialized. This is accomplished using the Composer, Elmo’s Windows-based software
application. Install the application and then perform setup and initialization according to the
directions in the Composer Software Manual.

4.12. Heat Dissipation

The best way to dissipate heat from the Solo Hornet is to mount it so that its heat sink faces up.
For best results leave approximately 10 mm of space between the Solo Hornet's heat sink and
any other assembly.

4.12.1. Solo Hornet Thermal Data

Heat dissipation capability (θ): Approximately 10 °C/W.

Thermal time constant: Approximately 240 seconds (thermal time constant means that

the Solo Hornet will reach 2/3 of its final temperature after 4 minutes).

Shut-off temperature: 86 °C to 88 °C (measured on the heat sink)