68
5.6.3.
Analog Input
Feature
Details
Maximum operating differential voltage
± 10 V
Maximum absolute differential input voltage
± 16 V
Differential input resistance
3.74 kΩ
Analog input command resolution
14-bit
5.7. Communications
Specification
Details
RS-232
Signals:
•
RxD , TxD , GND
•
Full duplex, serial communication for setup and
control.
•
Baud Rate of 9,600 to 57,600 bit/sec.
Differential RS-232
(RS-422)
Signals:
•
RxD , TxD , GND
•
Full duplex, serial communication for setup and
control.
•
Baud Rate of 9,600 to 57,600 bit/sec.
CAN
CAN bus Signals:
•
CAN_H, CAN_L, CAN_GND
•
Maximum Baud Rate of 1 Mbit/sec.
Version:
•
DS 301 V4.01
Layer Setting Service and Protocol Support:
•
DS 305
Device Profile (drive and motion control):
•
DS 402
5.8. Pulse-Width Modulation (PWM)
Feature
Details
PWM resolution
12-bit
PWM switching frequency on the load
2/Ts (factory default 22 kHz on the motor)