5.6.3.

Analog Input

Feature

Details

Maximum operating differential voltage

± 10 V

Maximum absolute differential input voltage

± 16 V

Differential input resistance

3.74 kΩ

Analog input command resolution

14-bit

5.7. Communications

Specification

Details

RS-232

Signals:

RxD , TxD , GND

Full duplex, serial communication for setup and

control.

Baud Rate of 9,600 to 57,600 bit/sec.

Differential RS-232
(RS-422)

Signals:

RxD , TxD , GND

Full duplex, serial communication for setup and

control.

Baud Rate of 9,600 to 57,600 bit/sec.

CAN

CAN bus Signals:

CAN_H, CAN_L, CAN_GND

Maximum Baud Rate of 1 Mbit/sec.

Version:

DS 301 V4.01

Layer Setting Service and Protocol Support:

DS 305

Device Profile (drive and motion control):

DS 402

5.8. Pulse-Width Modulation (PWM)

Feature

Details

PWM resolution

12-bit

PWM switching frequency on the load

2/Ts (factory default 22 kHz on the motor)