I/os, Digital input interfaces – ElmoMC ExtrIQ Digital Servo Drives-Solo Hornet User Manual

Page 66

Advertising
background image

Solo Hornet Installation Guide

Technical Specifications

MAN-SOLHRNIG (Ver. 1.003)

www.elmomc.com

66

5.6. I/Os

The Solo Hornet has:

4 Digital Inputs

2 Digital Outputs

1 Analog Input

5.6.1.

Digital Input Interfaces

Feature

Details

Type of input

Optically isolated

All four inputs share one signal return

line

Input current for 5 V DI level

R

in

=1.43K, I

in

= 2.8 mA @ V

in

= 5 V

Input current for 24 V DI level

R

in

=10.52k, I

in

= 2.2 mA @ V

in

= 24 V

High-level input voltage

5 V < V

in

< 24 V

Low-level input voltage

0 V < V

in

< 1 V

Minimum pulse width

> 4 x TS, where TS is sampling time

Execution time (all inputs):
the time from application of voltage on
input until execution is complete

If input is set to one of the built-in functions —
Home, Inhibit, Hard Stop, Soft Stop, Hard and
Soft Stop, Forward Limit, Reverse Limit or
Begin — execution is immediate upon
detection: 0<T<4xTS
If input is set to General input, execution
depends on program.
Typical execution time: ≅ 0.5 msec.

High-speed inputs – 5 & 6 minimum pulse
width, in high-speed mode

T < 5 µsec

Notes:

Home mode is high-speed mode and

can be used for fast capture and

precise homing.

High speed input has a digital filter set

to same value as digital filter (EF) of

main encoder.

Highest speed is achieved when

turning on optocouplers.

Advertising