HMC Electronics ASG-SD2500-10FX-SY X-PAQ Precision Fastening System User Manual

Page 10

Advertising
background image

Page 10

7. Bolt Sequence Steps:

Displays the sequence step and selected parameter. The parameter

name will be highlighted red, yellow, or green at the end of its cycle to

show its status.

8. Setup Button:

Takes you to screens where you may set up Tasks, Parameters, Bolt

Sequences, Inputs, Outputs, and System Settings.

9. Graph Button:

Displays the most recent fastening cycle graphically as Torque vs. Time,

Angle vs. Time, Torque vs. Angle, Speed vs. Time, and Power vs. Time.

10. Data Button:

Displays a table that contains rundown characteristics for the last 100

fastening cycles. Additional data is available in the internal memory and

can be downloaded to a USB flash drive from this screen as well.

11. Repeat Button:

Depressing this button keeps the controller on the current bolt in a

batch. The bolt sequence will not advance to the next bolt until the

button is released.

12. Reset Button:

Depressing this button resets the fastening bolt count in the event of a

failure, retry lockout, user request. The reset button also resets any

outputs. This button can be disabled when the controller is locked with

a password.

13. Outputs:

Displays (1) radio button for each of the (8) available outputs. The

appropriate radio button will illuminate blue when the output is active.

Documentation Provided By HMC Electronics