Parameter setup – HMC Electronics ASG-SD2500-10FX-SY X-PAQ Precision Fastening System User Manual

Page 14

Advertising
background image

Page 14

Parameter Setup:

From the task setup screen, select the Parameters button. Shown will be a button for each of the 8

available parameters for that task.

Some useful definitions for the Parameter Setup:

Target Torque/Angle: The value at which the tool should stop the fastener rundown

Torque HL/LL:

The High Limit (HL) or Low Limit (LL) of acceptable torque for the fastener in the

user’s process.

Angle HL/LL:

The High Limit (HL) or Low Limit (LL) of acceptable angle for the fastener. In

Torque Control Profiles, this monitoring may be disabled by tapping the ‘Angle

Monitoring’ radio button.

Threshold Torque:

The torque reading at which the tool enters the fastening cycle. Once the tool

reaches the threshold torque, it will count the angle of revolution until either

the final torque or final angle (depending on Torque or Angle Profile).

Run Down Speed:

The speed (rpm) that the tool will run (RH or LH rotation) from the time the tool

is triggered until either the final target is met, or the downshift point is met (if

enabled).

Downshift Torque:

The torque at which the tool will shift from the run down speed to the

downshift speed.

Downshift Speed:

An optional second speed that the tool may slow down to at a defined torque

limit. This can be disabled by tapping the ‘Enable Downshift’ radio button.

Param Timeout:

The time (in seconds) between when the tool is triggered and when it will shut

off on its own if the threshold torque is not reached to enter a fastening cycle.