Graph Screens

In order to assist the user with setting up and trouble-shooting problem joints, the latest rundown is

stored in the controller in graph form. From the ‘Run Tool’ screen, tap the ‘Graph’ button at the bottom

of the screen. Along the bottom of the screen can be found the available graphs, tap the appropriate

button to view:

• Torque vs. Time: Graphs the last rundown with Torque on the Y axis in whatever units are

specified in the parameter, and Time on the X axis in milliseconds (ms).

• Angle vs. Time: Graphs the last rundown with Angle on the Y axis in degrees (deg), and Time on

the X axis in milliseconds (ms).

• Torque vs. Angle: Graphs the last rundown with Torque on the Y axis in whatever units are

specified in the parameter, and Angle on the X axis in degrees (deg).