HYDAC HMG 3010 User Manual
Page 62
HMG 3010
Page 62
Edition 11/2011 - V04 R01
Part No.: 669855
Display all:
Display all renders the recording throughout
the entire recording period with all the meas-
ured values. This option is used, for exam-
ple, to restore the original condition of a re-
cording. Display All + OK restores the
measurement throughout the entire time
period along with the complete measurement
range scaling if the ranges had been previ-
ously limited.
Settings:
Settings will display the measurement
channels which have been used to make the
recording. The channel rendered along the
y-axis in the measurement curve is addition-
ally labelled with "(Y)".
For rendering as a graph you can activate or
deactivate a channel by checking or un-
checking the box in front of it using the ar-
row keys + OK (checkmarked means that
the channel will be shown). This enables you
to specify whether all measurement chan-
nels are to be shown, or only one or two at a
time. This feature enables you to keep track
when several measurement channels are
used (cf. example on left: "Tank" is deacti-
vated).
For curve rendering, there are additional
settings apart from which channels or sen-
sors are to be shown (on/off), e.g.
• Upper and lower limit
• Colouring and rendering of curves and
values
• Time range