Hmg 3010 – HYDAC HMG 3010 User Manual

Page 75

Advertising
background image

HMG 3010

Page 75

Edition 11/2011 - V04 R01

Part No.: 669855

6.5.1.2 Voltage supply ZBE 3010

Under the following conditions the CAN adapter
ZBE 3010 must have a separate voltage supply.

-

A CAN bus subscriber with a current
consumption of ≥ 100 mA is directly connected.

- The entire voltage for the connected bus system

is to be supplied via the ZBE 3010.

To supply voltage to the ZBE 3010 the HMG 3010
power supply (Part No.: 6054296) can be used.

Pin Signal
Male

0 V (GND)

Female +18 V (+U

B

)





6.5.2 Main menu CAN bus

Navigate via
¾

Settings

¾

Change settings of measurement

channels

¾

Channel D - CAN bus

to reach the main menu for CAN functionality
and to be able to adapt this to your
requirements.

If "Channel D CAN bus" is selected, the dis-
play jumps to the following window.



6.5.2.1 Sub-channel 01 .. Sub-channel 32

In this window you can activate and then
configure up to 32 CAN-messages (Sub-
channels). These messages are then evalu-
ated by the HMG like "normal" measurement
channels (measured values).



6.5.2.2 Configuring the message

When you have selected and activated a
message (sub-channel), the configuration
window will open, as shown on the right.

Advertising