7 Parameterization
Input mask
To open this window, use the
(Input mask) button:
This window is used to configure the input mask for each of the (max.) 50 parameters (mask 1
to 50).
Parameters
Parameter
Selection/settings
Description
Parameter act.
Not selected (empty)
Parameter not active
Selected (
)
Parameter active
Data type
Selection of data type
Float value
Floating parameter
Integer value
Integer parameter
Selection (selector)
Selector parameter
Boolean value
Boolean parameter
Name
(Empty)
(Max. 21 characters)
Name of the parameter
Unit
%
(Max. 5 characters)
Unit of the parameter
Min. limit
-2147483648 to 0 to
2147483647
Minimum value for value analysis
or
(Range depends on data type)
-3.37E+38 to 0 to +3.37E+38
Max. limit
-2147483648 to 100 to
2147483647
Maximum value for value analysis
or
(Range depends on data type)
-3.37E+38 to 100 to +3.37E+38