How to configure the communication settings

OPC bus server for LECOM
Instead of using the system bus (CAN), you can also communicate with the target system

via LECOM. The corresponding communication settings are configured with the LECOM

configurator of the »L-force Loader«. The LECOM configurator is activated via

OptionsLECOM configurator....



Example: Configuring a point-to-point connection via LECOM

(C 16)

O

Tip!
For communication via the serial interface COM1, use the configuration file

"Default_COM1.lccfg" which is set by default in the LECOM configurator.
For detailed information on the LECOM configurator, please refer to the

DriveServer documentation.

Use of the diagnostics interface or Ethernet NRT on L-force 9400 Servo Drives
Instead of using the system bus (CAN), you can also communicate with the controllers of

the "L-force 9400 Servo Drives" series via the diagnostics interface X6 or Ethernet NRT.

r

The communication settings for the diagnostic adapter are configured with the

diagnostics configurator of the »L-force Loader«. The diagnostics configurator is

activated via OptionsDiagnostics configurator....

r

If you want to use Ethernet NRT for communication, open the IP address dialog box via

OptionsIP address... and enter the IP address of the controller.

Use of other OPC bus servers
For communication with the target system, you can also install other bus servers for the

DriveServer. For detailed information on this topic, please refer to the DriveServer

documentation.

Note!

LECOM does not support the parameter set transfer variant "Replacement

device".

Note!

Please note that some fieldbuses or OPC bus servers do not support all download

options. Programs and *.lc9 files can, for instance, only be downloaded with the