L-force Loader

Control via script files

Structure of the script file

30

DMS 4.0 EN - 07/2007

L

O

Tip!
The script is not tested for correctness before it is being processed, i.e. script

processing does not stop before an error occurs. The error can be analysed and

eliminated using the log file.

Communication settings - [COMMUNICATION] section

General settings - [COMMON] section

Key

Parameter

Baudrate

Baud rate of the system bus in kBaud.

• The baud rate selection in the script is optional.

• If the baud rate is not defined in the script, the value set in the system bus

configurator will be used.

Key

Parameter

NumberOfDevices

Number of the target systems to be programmed (max. 63).

ShowProcessing

Status window display:

0 = Status window not displayed (standard setting).

1 = Status window displayed.

MaxNumberOfErrors

The latest version no longer supports this entry and ignores it, if necessary (e.g. in older

script files).

ExitAfterDownload

Automatic stop of »L-force Loader« after the script has been processed:

0 = »L-force Loader« does not stop after processing is completed (standard setting).

1 = »L-force Loader« stops after processing is completed.