L-force loader – Lenze Loader L-force Loader User Manual

Page 32

Advertising
background image

L-force Loader

Control via script files

Structure of the script file

32

DMS 4.0 EN - 07/2007

L

BinFile

Path and file name of the DDS binary file for the download.

• Not indicated for target systems without PLC functionality.

• File indication is optional (only indicated files will be transferred to the target

system).

AddDataFile

Path and file name of the application data for the download.

• Not indicated for target systems which do not support the download of

application data.

• File indication is optional (only indicated files will be transferred to the target

system).

ParameterSetFile

Path and file name of the GDC parameter set file for the download.

• File indication is optional (only indicated files will be transferred to the target

system).

ApplicationFileSet

Path and file name of the L-force Loader file (*.lfl) for the download.

• Only required for controllers of the "L-force 9400 Servo Drives" series.

DuplicateParameterSet

Determines whether a parameter set is to be duplicated or whether the target

system is a replacement device:

0 = Target system is a replacement device (standard setting).

1 = Parameter set is duplicated.

Note:

• LECOM does not support the "Replacement device" function!

• This key is not evaluated for controllers of the "L-force 9400 Servo Drives" series.

Here the decision about which parameters are to be transferred is already made

in the Engineer at the export of the download data.

StartAfterDownload

Determines whether the PLC program/L-force 9400 application is to be started after

download and parameter set transfer have been completed:

0 = PLC program/application not started (standard setting).

1 = PLC program/application started.

Key

Parameter

Advertising