L-force Loader

Operation

How to configure the communication settings

16

DMS 4.0 EN - 07/2007

L

5.1.1

Example: Configuring a point-to-point connection via LECOM

M

How to configure a point-to-point connection via LECOM:

1. Select ProgramsLenzeL-force Loader - 4.0L-force Loader from the Start menu

to start the »L-force Loader«.
In the »L-force Loader«:

2. Select OptionsDriveServer configurator to open the »DriveServer configurator«.

In the »DriveServer configurator«:

3. Select FileConnect to build up a connection to the selected DriveServer.

• Wait until the Please wait dialog disappears and the connection to the

DriveServer has been built up.

4. Select ConfigurationBus server to open the Bus server configuration dialog box.

• The right list field lists all bus servers which have been assigned to the

DriveServer.

• To remove an assignment, select the corresponding bus server from the right

list field and click the Delete button.

5. Click Refresh to list all bus servers available on the selected PC in the left list field.
6. For LECOM, select "Lenze OPC LECOM server" from the left list field and click Add to

assign this bus server to the DriveServer.
• If necessary, repeat the above steps to assign further bus servers to the Drive

Server.

7. Click OK to accept the settings and close the Bus server configuration dialog box.

• The bus servers assigned to the DriveServer will be listed in the name area under

the "Online" element.

8. Select FileDisconnect to end the connection to the selected DriveServer.
9. Select FileExit to exit the »DriveServer configurator«.

Note!

The configuration described below only has to be carried out once.