Lenze Loader L-force Loader User Manual
Page 17
L
DMS 4.0 EN - 07/2007
17
L-force Loader
Operation
How to configure the communication settings
In the »L-force Loader«:
10. Select OptionsLECOM configurator to open the »LECOM configurator«.
In the »LECOM configurator«:
11. Click OK to confirm the Lenze OPC server LECOM info dialog box.
• The configuration saved last will be loaded automatically.
12. Select the configuration entry for the interface (COMx) from the tree/list on the
left.
• Check the interface settings in the Communication port tab (particularly, COM
number and baud rate) and adjust the settings, if necessary.
• For a point-to-point connection via LECOM, mark the Scan at the server's start
option with a tick.
13. Select FileSave to save the configuration.
14. Select FileExit to exit the »LECOM configurator«.
The configuration is now complete and you can start searching for connected
devices in the »L-force Loader«.