L-force Loader

Operation

How to configure the communication settings

In the »L-force Loader«:

10. Select OptionsLECOM configurator to open the »LECOM configurator«.

In the »LECOM configurator«:

11. Click OK to confirm the Lenze OPC server LECOM info dialog box.

• The configuration saved last will be loaded automatically.

12. Select the configuration entry for the interface (COMx) from the tree/list on the

left.
• Check the interface settings in the Communication port tab (particularly, COM

number and baud rate) and adjust the settings, if necessary.

• For a point-to-point connection via LECOM, mark the Scan at the server's start

option with a tick.

13. Select FileSave to save the configuration.
14. Select FileExit to exit the »LECOM configurator«.

The configuration is now complete and you can start searching for connected

devices in the »L-force Loader«.