Appendix

Error numbers, causes & remedies

38

DMS 4.0 EN - 07/2007

L

C602h

Error while identifying the FIF.

(Product code cannot be read.)

Check the communication parameters.

If the problem still occurs, contact the Lenze

Hotline.

C603h

Error while identifying the FIF.

(ID cannot be read.)

C604h

Error while copying the application data.

Check the name of the target system causing

the error (e.g. "DEVICE001") in the log file and

the specifications in the script file.

C605h

Application data of file and target system is

identical.

Only status message, no remedy required.

C606h

Application data cannot be transferred.

Repeat the download.

If the problem still occurs, contact the Lenze

Hotline.

C607h

Error while opening the application data.

Check the name of the target system causing

the error (e.g. "DEVICE001") in the log file and

the specifications in the script file.

C608h

No target system selected.

Check whether a target system has been

selected.

C60Ah

Internal program error: OPC item cannot be

created.

Restart »L-force Loader«.

If necessary, restart PC.

C60Bh

Internal program error: OPC item cannot be

read.

Restart »L-force Loader«.

Check whether the target system can be

addressed.

C60Ch

Internal program error: OPC item cannot be

written.

Reinstall »L-force Loader«.

If the problem still occurs, contact Lenze.

C60Dh

Internal program error: OPC control.

Restart PC.

Reinstall »L-force Loader«.

C60Eh

Error while reading a file.

Check the path of the parameter file.

Communication and download errors
D100h

Error during the start of the "OPC Ctl"

component.

• Component has not been installed or has

not been correctly registered.

Reinstall »L-force Loader«.

D101h

No connection to the OPC server.

Check that the OPC server has been installed

correctly.

Reinstall »L-force Loader«.

D102h

OPC server is not in status "Running".

Restart PC.

D103h

Error while creating an OPC item.

Reinstall »L-force Loader«.

D104h

Error while downloading.

The error message contains causes and

information about troubleshooting.

D105h

Error while connecting to the OPC server.

Restart PC / reinstall »L-force Loader«.

D106h

Error while disconnecting from the OPC

server.

Restart PC / reinstall »L-force Loader«.

Error number

Cause

Remedy