Appendix

Error numbers, causes & remedies

C300h

Error while downloading the DDS binary file. Repeat the download.

If the problem still occurs, contact the Lenze

Hotline.

C301h

The target system found on the bus does not

correspond to the target system for which

the DDS binary file has been created.

Check the device address or select a different

DDS binary file.

C302h

The project on the target system is a newer

version than the project to be loaded.

C303h

Downloading of the DDS binary file has been

cancelled.

Repeat the download.

If the problem still occurs, contact the Lenze

Hotline.

C304h

Internal program error

(PLC program buffer cannot be created.)

Restart the program.

If the problem still occurs, contact the Lenze

Hotline.

C400h

The device description assigned to the GDC

parameter set file cannot be found.

Check the settings for the GDC search path in

the initialisation file (key "SearchPathPDB").

If the problem still occurs, contact the person

who created the GDC parameter set file.

C401h

Internal program error.

(Transfer list not yet created.)

Restart the program.

If the problem still occurs, contact the Lenze

Hotline.

C402h

The maximum permissible number of errors

has been exceeded during the parameter

transfer.

Repeat the parameter transfer.

If necessary, increase the number of

permissible errors in the initialisation file

(key "MaxTransferErrors").

C403h

The preparations for the parameter transfer

have failed.

Restart the program.

If the problem still occurs, contact the Lenze

Hotline.

C404h

The device description does not correspond

to the target system found on the bus.

Check the device address. If the device

description has been loaded manually, select

a different device description. Otherwise,

select a different GDC parameter set file.

C405h

Internal program error.

(Transfer list cannot be created.)

Restart the program.

If the problem still occurs, contact the Lenze

Hotline.

C406h

The "pdb.ini" file cannot be read.

Check that the "pdb.ini" file is in the »L-force

Loader« program directory. If you cannot find

it in the directory, reinstall the »L-force

Loader«.

C407h

The GDC parameter set file has been created

for a newer device version than that found

on the bus.

Create a new GDC parameter set file for the

device version present on the bus.

C500h

Faulty script file (communication parameters

cannot be read).

Check the script file, especially the

[Communication] section.

C501h

Error while creating the log file.

Check the log file name entered in the

command line and try again.

C502h

Error while opening the script file.

Check the script file name entered in the

command line and try again.

C503h

Error while opening the DDS binary file.

Check the name of the target system causing

the error (e.g. "DEVICE001") in the log file and

the specifications in the script file.

C504h

Error while opening the GDC parameter set

file.

C600h

No connection to the target system.

Check the wiring between PC and target

system.

Restart the program.

C601h

The target system cannot be identified.

Contact the Lenze Hotline.

Error number

Cause

Remedy