1 parameter set transfer, Parameter set transfer, C 27) – Lenze Loader L-force Loader User Manual

Page 27: L-force loader

Advertising
background image

L

DMS 4.0 EN - 07/2007

27

L-force Loader

Operation

How to download data

5.5.1

Parameter set transfer

The function area provides the following functions for the download of GDC parameter set

files:

Assignment of device descriptions
The GDC parameter set file includes the codes to be transferred with the corresponding

initialisation values. The parameter set transfer, however, requires additional information

about the code type. This information is generated from the corresponding device

description.
The »L-force Loader« tries to assign these device descriptions automatically by searching

the directory which has been the source for the parameter set file for the corresponding

device description.

r

If a directory does not include the corresponding device description, the search will be

continued in the directories configured via the DriveServer menu commands

ConfigurationPDB paths....

Command

Function

Duplication of parameter set At the parameter set transfer, some codes of the parameter set are not transferred

to the target system. These are, among others:

• C0009 - AIF device address

• C0125 - AIF baud rate

• C0058 - Rotor position

All codes not transferred to the target system are listed in a note dialog before the

parameter set transfer starts.

Replacement device

Codes C0009, C0125 and C0058 are also transferred to the target system.

Note: LECOM does not support the "Replacement device" function!

Advertising