page 20 — MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13)

Reverse Pumping Procedure

1. Switch the pump into reverse. With pump speed at a

medium-slow (approx. 12 strokes per min.) try to pull

the “pack” back into the hopper with 5 or 6 reverse

strokes.

2. Remix the concrete in the hopper.
3. Switch the pump into forward. If it is still plugged, repeat

“Reversing” procedure three times.

4. If concrete still does not move, proceed to the Shuttle

Tube Inspection Procedure.

Shuttle Tube inspection procedure

1. Stop the pump. Turn off the engine.
2. The senior or most experienced operator must warn all

others to stand at least 20 feet away from the machine

and turn their heads to face away from the pump.

3. The operator will position himself beside the reducing

elbow at the pump outlet. Wearing safety glasses, slip

the end of a pry bar (24" length of reinforcing steel rod)

under the latch of the hose clamp and flip it up.

4. Carefully knock the end of the hose away from the

reducer.

5. Chip the concrete out of the reducer with the pry bar.

DANGER

Accumulator Pressure

Make sure the accumulator pressure

gauge reads

ZERO psi. prior to

performing any maintenance or

inspection.You must follow lock

out-tag out procedures. Improper

accumulator pressure can result in

an explosion causing serious injury

or

death.

GEnERAL InfORMAtIOn

6. Remove the reducer. From the discharge end, chip

the concrete out of the shuttle tube with the pry-bar.

If concrete cannot be loosened from the outlet of the

shuttle tube, remove the clean-out plug on the bottom

of the hopper to discharge the concrete.

7. Chip the blockage out with the pry-bar.
8. Flush the shuttle tube with water.
9. Before resuming operation of the pump, perform the

“Reverse” Pumping Procedure to relieve pressure on

the shuttle tubes.