Troubleshooting (electrical) – Multiquip LS-600P User Manual

Page 77

Advertising
background image

MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) — page 77

tROubLEShOOtInG (ELEctRIcAL)

Troubleshooting (electrical)

Malfunction Reading (Screen 1)

Possible Problem

Solution

Main A OPEN

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Main A SHORTED

The 12-volt cycling solenoid is shorted

directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Main B OPEN

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Main B SHORTED

The 12-volt cycling solenoid is shorted
directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Swing OPEN

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Swing SHORTED

The 12-volt cycling solenoid is shorted
directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Throttle solenoid open

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Throttle solenoid shorted

The 12-volt cycling solenoid is shorted
directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Fuel solenoid open

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Fuel solenoid shorted

The 12-volt cycling solenoid is shorted
directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Advertising