MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) — page 51

Heat Exchanger Cooling Fan

This section is intended to make sure the cooling fan is

working properly. Under normal conditions the fan should

be running any time the engine is turned on.

Pressure Test

1. To determine the pressure of the hydraulic system,

set the

cylinder stroke control switch (Figure 57) to

the

JOG position.

Figure 57. Cylinder Stroke

Control Switch (JOG)

2. Place and hold the

manual cylinder jogging switch

(Figure 58) to either

JOG “A” or JOG “B” position to

test the pressure of that cylinder.

Figure 58. Manual Cylinder Jogging Switch

NOTICE

If the hydraulic oil temperature exceeds 170° F (77° C),

shut down the pump.

DO NOT continue to operate the

pump. Failure to shut down the pump will result in severe

damage to the pump.

AUTOMATIC

JOG

CENTER

OFF

JOG

“A”

JOG

“B”

CYLINDER STROKE

MAIntEnAncE

3. The

pumping pressure gauge (Figure 59) should

read approximately 4300 ~ 4400 PSI.

Figure 59. Pumping Pressure Gauge

Long Term Storage (pump)

„

Remove the battery.

„

Drain the fuel tank completely. Treat with a fuel stabilizer

if necessary.

„

Clean exterior with a cloth soaked in clean oil.

„

Store unit covered with plastic sheet in moisture and

dust-free location out of direct sunlight.

Long Term Storage (Trailer)

1. Check brake system for proper fluid level in master

cylinder and bleed all lines.

2. Lubricate all links and pivots to prevent any rusting.
3. Remove wheel and drum assemblies and spray a good

anti-corrosion compound (CRC formula 5-56) under

rubber boot on forward end of brake wheel cylinder.

Avoid spraying drum and brake lining.

4. Grease all bearings and reinstall wheel and drum

assemblies.

5. Make sure breakaway cable is fully released.
6. After extended storage, refer to the Maintenance Steps

listed above to insure that the trailer is ready for towing.

0

PUMPING

PRESSURE

1000

2000

3000

5000

4000

CaUTiON

NeveR store the pump with fuel in the tank for any

extended period of time.

ALWAYS clean up spilled

fuel immediately.