MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) — page 37

4. Reinstall the control panel and tighten the 2 retaining

screws.

5. On the top of the unit, to the right of the control box

(Figure 37), hammer out the knock-out hole and install

the remote antenna.

Figure 37. Antenna Installation

6. Connect the antenna cable to the connector on the

rear (Figure 37) of the control box.

Radio Remote Control Buttons Operation

Before the remote control hand-held module can be used,

the

pumping control switch on the control box must be

placed in the

REMOTE position ()Figure 38.

Figure 38. Pumping Control Switch (Remote)

ANTENNA

KNOCK-OUT

HOLE

ANTENNA

CONNECTOR

CABLE

CONTROL BOX

CONNECTOR

REAR OF

CONTROL BOX

LOCAL

REMOTE

CENTER

OFF

Remote pumping operation can be performed by the hand-

held radio remote control (Figure 39).

Figure 39. Radio Remote Control

The buttons on the hand-held remote control module have

the following functions:

„

ON/OFF – Turns the power on or off. When power is on

the power LED lights red. If the battery LED turns red,

9V battery needs to be replaced.

„

E-STOP – Turns off the pump completely in an

emergency.

„

pUMp ON/Off – Starts and stops the forward pumping.

„

pUMp Rev – momentarily pumps in reverse direction.

„

vOLUMe (+) – used to increase the pumping volume.

„

vOLUMe (-) – used to decrease the pumping volume.

E-STOP

ON

OFF

PUMP

REV

VOLUME

VOLUME

PUMP

ON/OFF

POWER LED

NOTE: OLDER MODELS
MAY INDICATE
INSTEAD OF

FLOW

VOLUME

BATTERY LED

OPERAtIOn