MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) — page 33

OPERAtIOn

Starting Procedure

1. Locate the

emergency stop switch (Figure 20) on

the

digital control panel. Turn the emergency stop

switch clockwise and release (open). This will allow

the engine to start.

Figure 20. Emergency Stop Switch

2. Place the

cylinder stroke control switch in the

aUTOMaTiC position (Figure 21).

Figure 21. Cylinder Stroke Control Switch

(Automatic)

3. Place the

pumping control switch in the CENTER

OFF position (Figure 22) for normal pumping operation.

Figure 22. Pumping Control Switch (OFF)

WaRNiNg

DO NOT attempt to operate this concrete pump until

the Safety, General Information and Inspection sections

have been read and understood.

E

m

erg

ency S

top

NOTICE

If the

emergency stop switch is in the closed position

(

STOP), engine will not start. To start the engine, make

sure the emergency stop switch is in the

OPEN position

(fully extended).

AUTOMATIC

JOG

LOCAL

REMOTE

CENTER

OFF

4. Place the

direction control switch to the FORWARD

position (Figure 23).

Figure 23. Direction Control Switch

(FORWARD)

5. To start the engine, insert the ignition key (Figure 24)

into the ignition switch and turn the key to the

ON

position.

Figure 24. Ignition Switch

6. When the ignition key is in the

ON position, the digital

readout screen (primary) will cycle through 3 displays

as shown in Figure 25.

Figure 25. Primary Screen (Ignition Key ON)

7. Turn the key to the

START position and listen for the

engine to start. In warm weather let engine warm up

for 5 minutes. In cold weather, let engine warm up for

10 minutes.

FORWARD

REVERSE

IGNITION

ON

OFF

START

LS 600 OFF

0000 ENG RPM

BATTERY 12.5 V

LOW OIL PSI

1

LS 600 OFF

0000 ENG RPM

BATTERY 12.5 V

LOW RPM FAULT

1

LS 600 OFF

0000 ENG RPM

BATTERY 12.5 V

END OF MESSAGE

1