Maintenance – Multiquip LS-600P User Manual

Page 49

Advertising
background image

MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) — page 49

MAIntEnAncE

Figure 56. Wear Plate and Cutting Ring

Changing the Concrete Cylinder Piston Cups

The

urethane piston cups will occasionally require

replacement depending on the following factors.

„

The fluid level and cleanliness of the lubrication box.

„

The size and type of aggregate.

„

The type of concrete being pumped.

It is time to replace the cups when increasingly large

particles of sand and cement pass into the lubrication box.

DO NOT allow the cups to become so worn that they begin

to pass lubrication into the material cylinders.
If the liquid level of the lubrication box becomes to low, the

rubber cups will severely deform due to excessive heat.

Whenever replacement is due, both cylinder cups should

be replaced.

GOOD SEAL

LEAKING

SHUTTLE TUBE

(INSIDE HOPPER)

RUBBER

ENERGIZER

WEAR

PLATE

CUTTING

RING

Cylinder Cup Replacement Procedure

1. Remove the two hydraulic hoses connected to the

remix motor. Plug the ports with fittings (not provided)

to prevent hydraulic hose leakage.

2. Remove the hopper discharge nipple and loosen sleeve

seal. Inspect and replace if wear is excessive.

3. Remove the two tie rod nuts and the four eyebolt nuts

securing the hopper to the pump frame.

4. Using an approved lifting device, remove the hopper

using extreme care not to damage the hopper seal.

5. Start the engine and turn on the pressure test switch.

Cycle pump in reverse until hydraulic system obtains

maximum pressure, then turn pump and engine

off.

6. Remove ignition key and disconnect battery.

Think

safety! Check the hydraulic gauges on panel and make

sure accumulator pressure reads zero. One piston

should be in the fully discharged position at the end

of the concrete cylinder.

DANGER

aMpUTaTiON HazaRD

D u r i n g r o u t i n e

m a i n t e n a n c e o r

removing material

blockage, you will be

required to put your

hand in the concrete

cylinders or near the

shuttle tube. You are at

extreme risk of injury or

aMpUaTiON if the engine is running or if pressure is

in the hydraulic system.
Prior to performing any maintenance on the pump,

follow described lock out-tag out procedures. Stop the

engine by turning off the ignition switch and remove

the starter key.
Place a

DO NOT OPERATE tag over the switch and

disconnect the battery. The pressure reading on

the accumulator pressure gauge

MUST read zero.

ALWAYS make sure the accumulator circuit pressure

reads zero prior to performing any maintenance on

the pump.

Advertising