Specifications – RKI Instruments GX-2009 Manual User Manual

Page 7

Advertising
background image

GX-2009 Operator’s Manual

Specifications • 2

Specifications

Table 1: Model GX-2009 Specifications

Target Gas

Combustibles,
Methane (CH4)
calibration
standard*

Oxygen (O

2

)

Hydrogen
Sulfide
(H

2

S)

Carbon
Monoxide
(CO)

Range
(Increment)

0-100% LEL
(1% LEL)

0-40.0 vol%
(0.1 vol%)

0-100.0 ppm
(0.5 ppm)

0-500 ppm
(1 ppm)

Detection
Method

Diffusion

Response
Time

T90 Within 30 Seconds

Accuracy

± 5% of reading

or ± 2% LEL

(whichever is

greater)

± 0.5% O

2

± 5% of

reading or

± 2 ppm H

2

S

(whichever is

greater)

± 5% of

reading or

± 5 ppm CO

(whichever is

greater)

Display Digital

LCD

Gas Alarms
(Factory
Settings)

Alarm 1: 10%
LEL
Alarm 2: 50%
LEL
Over: 100%
LEL

Alarm 1: 19.5
vol%
(Decreasing)
Alarm 2: 23.5
vol%
Over: 40.0
vol%

Alarm 1: 5.0
ppm
Alarm 2: 30.0
ppm
Over: 100.0
ppm
TWA: 1.0 ppm
STEL: 5.0 ppm

Alarm 1: 25
ppm
Alarm 2: 50
ppm
Over: 300 ppm
TWA: 25 ppm
STEL: 200
ppm

Operating
Temperature
and Humidity

-20 to 50

o

C/Below 85% RH (Without Condensation)

Safety/
Regulatory

C US

186718

CSA classified, “C/US”, as Intrinsically Safe. Exia. Class I, Groups A,

B, C, & D. Class I, Zone 0, Group IIC. Temperature Code T3C.

Power Supply

NiMH Batteries (2.4 VDC Nominal), Direct Charging