Controlling the thermostat – Sensaphone 400 User Manual

Page 107

Advertising
background image

Chapter 8: Controlling the Output

105

Step 2: mount the Sensaphone 400.
Choose a location for your Sensaphone that allows for easy wiring to the

thermostat, such as near your heater/air conditioning system. Mount the

unit on a wall or flat on a desktop or table surface. Plug in the power sup-

ply and connect the telephone line.
Step 3: Connect cable from thermostat to Sensaphone 400.
This Sensaphone 400 has a terminal strip below the input/output wiring

door that will connect to the 12VDC power supply and X & C terminals

of the thermostat (See Figure 1). This connection is required to switch the

thermostat between normal and vacation modes. Run a two-conductor

cable from the thermostat to the Model 400. On the thermostat, connect

the red wire to the X (+) terminal, and the black wire to the C (-) terminal.

On the 400, connect the red wire to the NO terminal. Connect the black

wire to the negative wire from the power supply. Use a wire nut to complete

this connection. Connect the positive wire from the power supply to the

“C” terminal on the model 400.

— Rc
— Y

— G
— X

— C

12V

Thermostat

shielded accessory cable

12VDC
Power Supply

red

black

-

+

1 C

ZONES

2 C

3 C

4 C

NO C NC

— Rh
— W

+

-

Step 4: Program the Thermostat.
Refer to the manufacturers instructions for programming the thermostat.

Be sure to program settings for both normal and vacation modes.

Controlling the Thermostat

The operating mode of the thermostat (normal/vacation) can be controlled

at the Model 400 keypad or remotely via Touch-Tone comands. Both

methods are described below:

Advertising