Sensaphone 400 User Manual

Page 128

Advertising
background image

126

SENSAPHONE 400 User’s Manual

power Supply
Power Supply
: 120VAC/9VDC 60Hz 6W wall plug-in transformer w/6’

cord.
Power Consumption: 1.5 Watts
Power Protection: Metal Oxide Varistor
Battery Backup: Six size-C alkaline batteries (not included), providing up

to 24 hours of back-up time.

envIronmental
Operating Temperature
: 32–122° F (0–50° C)
Operating humidity: 0–90% RH non-condensing
Storage Temperature: 32°–140° F (0–60° C)

phySICal
Dimensions
: 2.1”h x 7.8”w x 8.8”d
Weight: 2 lbs.
Enclosure: Indoor-rated plastic housing suitable for wall or desktop instal-

lation.
Alarm: Off when no alarm exists. Blinks when an unacknowleged alarm

exists. On steady when an acknowledged alarm exists
Battery Ok: On steady when the battery is in good condition. Blinks when

the battery is low. Off when the battery must be replaced.

StandardS
- FCC Part 15 Class B, USA Emission Standards
- FCC Part 68 (47 C.F.R. Part 68), USA Telecommunications Standards
- ICES-003 Issue 4 Class B, Canadian Emission Standards
- Complies with CS-03 Issue 8, Canadian Telecommunications Standards
- NRTL Listed for compliance to UL60950-1, USA Safety Standards
- NRTL Listed for compliance to CSA C22.2 No. 60950-1, Canadian Safety

Standards

Advertising