Contactor Product Description

1-7

1502-UM051E-EN-P – June 2013

Contactor

Specifications

Table 1.B - Bulletin 1502 Medium Voltage 800 Amp Contactor Ratings

Description

Specifications

Voltage Ratings
Maximum Rated Voltage

7200

System Voltages

2400

3300

4160

4800

6600

6900

Dielectric Voltage Withstand Rating

For 60 seconds (kV)

18.2 / 20 (IEC)

Basic Impulse Level (B.I.L.) Withstand

Phase to Ground, Phase to Phase (kV)

60

Frequency Ratings

Hertz

50 / 60

Current Ratings
Rated Continuous Current (Amps)

800

2400 V (RMS Sym Amps)

12,500

5000 V (RMS Sym Amps)

12,500

Maximum Interrupting Current Rating

7200 V (RMS Sym Amps)

12,500

2400 V (Sym MVA)

50

5000 V (Sym MVA)

100

Maximum Interrupting MVA Rating

7200 V (Sym MVA)

150

Short-Circuit Withstand at Rated Voltage Current Peak ½ cycle (kA)

85

For 1 second (kA)

12.0

Short Time Current Rating Capability

For 30 seconds (kA)

4.8

Chop Current (Average RMS Amps)

0.5

Make and Break Capability at Rated Voltage (kA)

8.0

Ambient Temperature

°C

40

Contactor Coil Data (Series E)

Control Voltage

(V

CTL

)

Coil Voltage (V

CL

)

Close Current (A

DC

, 200 milliseconds)

12

Hold Current (A

DC

)

0.7

Pick-up Voltage

95

Drop-out Voltage

75

Trip Current (A

DC

, 200 milliseconds)

5.2

110 to 240 VAC

or

110 to 250 VDC

VAC:

V

CL

=

X V

CTL

(Max.)

VDC:

V

CL

= V

CTL

Trip Voltage

70

Close Current (A

DC

)

13.1

Hold Current (A

DC

)

0.24

Trip Current (A

DC

)

5.6

Pick-up Voltage

102

120 VAC

110 VDC

Trip Voltage

84

Contactor Coil Data (Series D)

Control Voltage

(V

CTL

)

Coil Voltage (V

CL

)

Coil Inrush Current (A) – Electrically Held

13.1 / 7.1

Coil Inrush Current (A) – Mechanical Latch

13.1 / NA

Coil Inrush Current (A) – Mechanical Latch Trip

5.6 / NA

Coil Continuous Current (A)

0.24 / 0.13

Coil Pick-up Voltage (VAC)

102 / 196

120 VAC/

230 VAC

110 VDC/

208 VDC

Coil Drop-out Voltage (VAC)

75 / 145

The voltage and current ratings listed are valid up to 1,000 m (3,300 feet). Please refer to Table 1.C – Altitude Derating Chart, on page

1-8 for ratings above this altitude.

Control voltage, as measured at the input of the IntelliVAC or IntelliVAC Plus control module.

Provided that regular maintenance is performed.

A contactor drop-out delay may be configured with the IntelliVAC control module (refer to publication 1503-UM053_-EN-P), or the

IntelliVAC Plus control module (publication 1503-UM054_-EN-P).

FDO = Fast Drop-Out. NDO = Normal Drop-Out.

The number of contactor auxiliary contacts depends on the contactor type. Some of the contacts are used in the typical control

schemes used.