Maintenance

4-9

1502-UM051E-EN-P – June 2013

Stop

Armature plate

Armature plate

makes contact

with Stop

Figure 4.10 – Return Spring Installation

16. With the contactor in the open position, measure the distance between the

bottom of the bearing and the top of the wear indicator line on all three

vacuum bottles with a feeler gauge. This dimension shall be 7.6 mm

(0.300 in.) minimum as shown in Figure 4.11.


Figure 4.11 – Vacuum Bottle Contact Gap (Front View)

Insulator

Wear indicator line

on operating shaft

7.6 mm

(0.30 in.)

Min.

Vacuum

Bottle

Advertising