5-6 Configuration and Programming

Configuration mode input image table

The data format of the input image table when the Module is in the
configuration mode is:

Input word 0:

bits 0-5, 8-10

identical to like numbered bits in output table

bits 6, 7 and 11 not used

bit 13

configuration error: 1

= error; 0 = no error

bit 14

Module OK: 1

= Module operational,

0

= fatal error encountered

bit 15

1 when in configuration mode
0 when in command mode

Input word 1:

bits 0-5

same as corresponding bits in output word 1

bits 6-15

not used

Input words 2 and 3 are identical to output words 2 and 3.

Invalid Configurations

The following configurations can be programmed, but are not
acceptable to the Module, and causes the configuration error, input